Hydra Facial Machine 14 in 1
   Technical specifications:
- Vacuum Pressure: >100 Kpa
- Maximum Power Output: 250 VA
- Input Voltage: 100–240 VAC, 50 Hz / 60 Hz
- Control Interface: Dual reference in documentation (10.4-inch / 15-inch Touchscreen)
- Net System Weight: 45 KG
- Hydro Dermabrasion & Photon Light: Main treatment modalities
- Radio Frequency (RF): Three-pole RF for tissue remodeling
- Thermal Management: Hot and cold hammer therapy
- Acoustic Energy: Ultrasonic and specialized ocular/eye ultrasound
- Mechanical Exfoliation: Microdermabrasion, shovel knife, and skin scrubber
- Micro-Needling: Electric automated micro-needle system
- Fluid & Gas Delivery: Vacuum pen, spray mist gun, and ion spray
- Electrophysiology: Bio microcurrent and high-frequency modalities
Category: Dermatology-Skin Care
Reviews (0)
Be the first to review “Hydra Facial Machine 14 in 1” Cancel reply
Shipping & Delivery
Related products
360 Magneto Optical Multi-Functional Beauty Machine
Technical Specifications:
- Input Power Consumption: 2000W to 3000W (depending on the exact sub-configuration).
- Input Voltage: AC 220V ±10% (50Hz) or AC 110V ±10% (60Hz).
- IPL / OPT (Hair Removal & Vascular): 640 nm to 1200 nm.
- IPL / OPT (Skin Rejuvenation & Acne): 530 nm to 1200 nm.
- Nd:YAG Laser (Tattoo & Pigment): Dual-wavelength configuration.
- 1064 nm: Targets dark, black, and blue inks.
- 532 nm: Targets red, brown, and brighter cosmetic pigments.
- 1320 nm: Used alongside carbon paste for specialized facial peeling ("Black Doll" facials).
- OPT / IPL Energy Density: 1 to 50 J/cm² (Fully adjustable).
- Nd:YAG Laser Energy: Up to 2000 mJ.
- Pulse Repetition Rate (Frequency): 1 to 10 Hz.
- Pulse Width / Duration: 1 to 8 ms.
- Standard Spot Size: 15 mm × 50 mm (large area option) or 12 mm × 30 mm.
- Control Center: Dual display screen configuration; primary interface features an 8-inch to 10.4-inch color LCD touch screen.
- Optical Lamp Lifespan: High-grade UK-imported xenon lamps offering approximately 400,000 to 1,000,000 shots per handle.
- Cooling Mechanisms: Continuous closed-loop system combining Water Cooling + Air Cooling + Semiconductor (TEC) Refrigeration.
- Crystal Interface Temp: Down to -5°C to -30°C to guarantee surface-level skin protection.
Brymill Cry-Ac Liquid Nitrogen Spray
Features:
- Comes with 5 Spray tips and 1 Curved tip
- Ergonomic design. Slim finger tip trigger for maximum control and easy viewing
- Suits left or right hand users
- Superior valve system operated for longer without clogging up with contaminants
- Durable stainless steel and solid brass construction
- Anti-topple flange for extra stability
- Larger size for greater capacity and longer holding time
- 500ml capacity
- 80 to 100 freezes and an average of 10 seconds each
- 29cm tall, weighs 895g when full
Diode Laser Hair removal system – BVLASER
Technical Specifications:
- Pressure Operating Range: 20 mmHg to 200 mmHg.
- Pressure Regulation: 10 adjustable digital increments.
- Inflation / Deflation Cycles: Pre-programmed multi-phase sequence loops.
- Therapy Duration Settings: 10, 20, or 30-minute settings with continuous operation option.
- Treatment Modes: 3 unique programmatic inflation vectors (Sequential squeezing, uniform compression, wave variants).
- Input Voltage Matrix: 100V–240V AC, ~50Hz / 60Hz universal utility supply.
- Power Draw Limitation: 18 Watts to 25 Watts maximum.
- Internal Battery Back-up: 14.4 VDC rechargeable lithium-ion battery.
- Standalone Operation: Provides up to 4 hours of continuous clinical delivery.
- Chassis Safety Grade: Internally powered, Type BF medical equipment rating.
- Primary Display Module: Color LED capacitive touchscreen interface.
- Chamber Mapping Indicator: Real-time LED graphical feedback mapping actively inflating air zones.
- System Redundancy: Dual CPU processors for automated safety tracking.
Fractional CO2 Laser – Lume Pro
Technical Data:
Wavelength:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 10600nm
Laser Power:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Max 60W
Working mode:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Pulsed, Ultra pulsed, Continuous
Mode structure:Â Â Â Â Â Â Â Â Â Â Â Â Â TEM00
Aiming beam:                   Red laser (630~650nm, ≤5mW)
Pulse duration:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 0.1~10ms
Spot diameter:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 100~2000um
Scanning mod:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Max 20*20mm
Scanning graphics:Â Â Â Â Â Â Â Â Â Â Circle, square, triangle, rectangle, hexagon, straight line
Beam delivery:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 7-joint articulated arm
Warranty:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 2 years (including handpiece)
LUMENIS ONE I IPL I Diode Laser I ND Yag Laser (3 in One) Refurbished
Laser Type: IPL, Nd:YAG, Diode
Wavelength:Â 515-1064 nm
Handpiece Available:Â IPL, Lightsheer(Diode), ND:Yag.
IPL:Â Optimal Pulse Technology (OPTâ„¢) , unique to Lumenis IPL, delivers the right pulse and fluence for each application. Multi- Interchangeable Expert Filters for the Universal IPL Treatment Head fr515nm to 755nm
IPL Applications:Â Photorejuvenation; Vascular Lesions; Pigmented Lesions; Permanent Hair Reduction
DIODE LASER: FDA-approved diode for permanent hair reduction on all skin types (I-VI), including tanned skin, and treatment of PFB.
Advanced Sapphire Contact ChillTipâ„¢ ensures patient comfort before, during and after each laser pulse.
LightSheer ® Module
Unsurpassed photoepilation with a wider range of applications.
Diode Laser Applications:Â Permanent Hair Reduction; Pseudofolliculitis Barbae
Multi-Spotâ„¢ Nd:YAG Module:Â Extraordinary effects for vascular lesions and leg veins.
Treatment for Cherry Hemangioma, Leg Veins, Vascular Lesions
Nd:Yag Laser Applications:Â Leg Veins; Deeper Vascular Lesions; Non-Ablative Treatment of Facial Wrinkles
MAGNIFYING LAMP WITH STAND
Multifunction 4-in-1 Dermatology Unit
Multifunctional 4 in One Dermatological Unit:Â
- Picosecond Laser (Advanced Pigment & Tattoo Removal)
- Radio Frequency / RF (Skin Tightening & Contouring)
- 360 Magneto-Optical (High-Efficiency Hair Removal)
- IPL / SHR (Photo rejuvenation & Hair Removal)
- Picosecond Laser Energy: 10 – 2000 mJ.
- Picosecond Pulse Width: Single digit picoseconds (significantly shorter and safer than the Nd:YAG nanosecond pulses of the first machine).
- IPL / OPT Energy Density: 1 – 50 J/cm².
- Frequency / Repetition Rate: 1 – 10 Hz adjustable sliding speed.
- Cooling Infrastructure: Enhanced multi-stage system featuring TEC Semiconductor Refrigeration + Air Cooling + Closed-Loop Water Circulation keeping the skin interface at sub-zero temperatures (-5°C to -10°C).
Portable Liquid Nitrogen Gun L-300
Medical Grade Liquid Nitrogen Gun L-300 Portable Liquid Nitrogen Cryotherapy Liquid Nitrogen Spray With 9 Heads
Liquid nitrogen freezing is widely used in various clinical departments of the hospital. The cold therapy instrument can be used in various clinical departments of the hospital to replace surgery, safe and non-toxic, harmless and less painful, does not damage healthy tissue, and has good sterilization effect.
Features:
Product name: beauty instrument liquid nitrogen sprayer
Material: stainless steel
Medium: liquid nitrogen
Actual volume: 250 ml
Accessories: nine freezing heads
Specification: 350*180*310 (mm)

Reviews
There are no reviews yet.