AEONMED VG70 ICU VENTILATOR
Automated external defibrillator – AED
Operational Features
Automatic Rhythm Analysis: Uses built-in algorithms to analyze the patient's heart rhythm through electrode pads and determine if a shock is necessary.
Audio and Visual Prompts: Provides step-by-step voice instructions and visual cues (like diagrams or flashing lights) to guide the user through pad placement, rhythm analysis, and shock delivery.
Shock Delivery Modes:
Fully Automatic: Delivers the shock automatically after a verbal countdown if required.
Semi-Automatic: Prompts the user to press a flashing shock button when a shockable rhythm is detected.
Biphasic Waveform Technology: Modern units deliver two sequential lower-energy shocks in opposite polarities, which is more effective and causes less tissue damage than older monophasic models.
Biphasic Defibrillator STAT-X Visor HealthCare U.K
The 4-in-1 design of the STAT-X Defibrillator Monitor brings multiple functions into one compact unit, offering significant space and cost savings while improving portability.
1. Manual Defibrillation 360j Adjustable
2. AED (Automated External Defibrillator)
3. Pacemaker
4. Monitoring
Defibrillation
Manual defibrillation modes include synchronous cardioversion and asynchronous defibrillation.
Having 7 Inches Multi Color Display
AED
The model applies patented analysis algorithm and automated analysis as well as convenient setting to guide clinical emergency personnel in providing defibrillation and basic life support.
Pacing
Having on-demand pacing and fixed pacing mode, for patients with cardiac arrest and acute severe slow arrhythmia, in vitro non-invasive pacing mode is rapid, easy to master, time-saving and improve recovery success rate.
Monitor
5-lead ECG monitoring as standard, optional monitoring functions include SpO2, NIBP, PR and EtCO2 are also available for continuous monitoring of patient vital signs.
Blood & Fluid Warmer – Q Warm MDX USA
TECHNICAL SPECIFICATIONS
-
- Model: Q-Warm
- Temperature setting: 35°C- 42°C
- Power supply: a.c.100~240V/50~60Hz
- Power consumption: Max. 85VA
- Type of protection against electric shock: Class I
- Degree of protection against electric shock: BF Applied part; Defibrillation-protected
- Degree of protection against ingress of liquids: IPX2
- Temperature accuracy: ±2.0°C
- Overheat protection: 42°C
- Low temperature alarm: 37°C
- Warming up time: From 20°C to 42°C approx 2 min
- Operating mode: Continuous
- Dimension (W*D*H): 180x70x35mm
- Net Weight: 0.4kg
BP Holter Monitor Cardio Check – MDX USA
The CardioCheck enables doctors to gain a thorough diagnosis of patients over the course of 24 hours where blood pressure is recorded at set intervals according to the doctos requirements.
The CardioCheck is a handheld ambulatory blood pressure monitor which is based on the oscillography principle and records BP over 24 hours. It can be used in a clinical setting, hospital ward or even home us.
Cardiac Monitor Critiview 360 – MDX USA
Technical Specifications:
1.12'' screen with true color, wide viewing angle, high brightness LCD display. 2. HR/PR, NIBP, RR, ECG, SpO2, TEM 3. Simple and friendly operating display interface. 4. Internal chargeable large capacity battery provides convenience for patients' moving. 5. Playback and browse function for long term waveform and monitor data record. 6. Optional printing output function, alarm triggers printing. 7. Auto double alarm with audible and visible signals 8. Anti-defibrillation, anti-interference from high frequency electric knife 9. A full-synchronistic lead multi-channel ECG display... 10. This medical equipment can be used in ICU, CCU and operation room. Optional - ETCO2, IBPx2, COCompression Therapy Astramed CT-01
Technical Specifications:
-
- Pressure Range: 20 to 200 mmHg
- Pressure Levels: 10 adjustable increments
- Therapy Timer: 10, 20, or 30 minutes free settings
- Massage Programs: 3 programmatic modes (Sequential squeezing & double wave variants) A Mode: Sequential Squeezing, B Mode: Double wave, C Mode: Double Wave
- Input Voltage: 100–240V AC (~50Hz / 60Hz universal power input)
- Power Consumption: 18 Watts
- Machine Size: 210 mm × 256 mm × 227 mm
- Machine Weight: Approximately 1.5 KGS
- Available Cuff Colors: Black, Grey, or custom tailored options
- Control Mechanism: Computer program automated process for pinpoint accurate pressure
- User Interface: Vibrant, color LED touch screen panel
- Monitoring: Direct chamber feedback via LED indicator lights while air chambers are actively inflating
- Portability: Integrated ergonomic pickup handle design for easy transit
Compression Therapy Venaflow 600 – Visor Healthcare U.K
Technical Specifications:
-
- Pressure Range: 0 mmHg to 280 mmHg.
- Screen Size: 4.3" Color touch TFT Screen
- Therapy Modes: Above 20 Therapy Modes , 8 Customizable
- Simultaneously : Simultaneously Compression of both Legs
- Maximum Pressure: 160 mmHg to 280 mmHg.
- Ultimate System Limit: ≤ 300 mmHg (with comprehensive over-pressure safety protection).
- Pressure Settings Accuracy: Adjustment steps of 5 mmHg with a strict tolerance error of ±5 mmHg.
- Therapy Timer: 0 min to 60 min (Timing error bounds: ±2% or ±1 min).
- Inflation Rate Control: 1 to 6 fully adjustable speed levels.
- System Leaks Tolerance: Maximum gas path air leakage rate ≤ 2 mmHg per second.
- Venous Filling Target: 20 seconds to 70 seconds cycle capability (Error: ≤ ±1s).
- Pressure Holding Interval: 1 second to 3 seconds hold duration (Error: ≤ ±0.5s).
- Aeration & Release Cycles: Aeration duration ≤ 25s; standard release timing ≤ 15s.
- Manual Pressure Relief Emergency: Drops down to 15 mmHg in ≤ 10 seconds.
- Power Parameters: Universal 100–240V AC input, operating at 50/60Hz ±1Hz frequency.
- Battery Architecture: Built-in 2200mAh rechargeable Lithium-ion battery pack.
- IPCT: Intermittent Pneumatic Compression Therapy
- DVT : Deep Vein Thrombosis Device
Digital 3 Channel ECG Machine – Cadiosense 303 Visor Healthcare U.K
Digital 3 Channel ECG Machine Cardiosense 303
Cardiosense 303 is a digital 3 channel ECG machine. Its high-performance parameters and low price make it the first choice for most users. It’s a high cost-effective digital 3 channel ECG machine.
with Glasco Algorithm
- Sampling rate: 32000Hz
- A/D shift: 24 bits
- 5-inch high resolution LCD screen with grid background
- The lightest 3 channel ECG, only 1.3kg
- ECG data can be saved as HL7, XML, PDF, PNG, JPG, DICOM, GDT or ZQECG format
- Support paperless records and storage of electronic cases, the machine stores more than 1000 cases
EBM-5 Electric Medical Bed
The EBM-5 is a high-end electric medical bed used in ICUs. It has five main functions, all controlled by a motor, allowing for adjustments to the backrest, leg rest, bed height, and specialized medical tilting positions for optimal patient care and recovery.
Key Functions & Specifications
The "5 functions" typically refer to the following motorized adjustments:
Backrest Lifting: Adjustable from 0° to approximately 70°–80°.
Knee/Leg Rest: Adjustable from 0° to approximately 30°–45°.
Height Adjustment: The entire bed can be raised or lowered (typically between 490mm and 790mm) to assist with patient transfers and caregiver ergonomics.
Trendelenburg Position: Tilts the bed so the feet are higher than the head (approx. 12°–15°).
Reverse Trendelenburg: Tilts the bed so the head is higher than the feet (approx. 12°–24°).
ECG Holter Monitor Cubix Holter – MDX USA
■Quick and accurate analysis system.
■With 3 leads synchro analysis, QRS search can be more exactly.
■ There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
■Optional main channel.
■ Agile and exact "Atrial Fibrillation" analysis.
■The function of pacing analysis could analyse all pacemakers.
■ Many pacine modules have been added.
■ Any period of single lead or 3-leads ECG can be reviewed at any time with the
function of fast waveform review and analysis.
■ The types of the analysis system of HR variability include five minutes of short
ECG and one hour or 24-hour of long ECG.
■ Print report expediently.
■ Perfect function of case management.
■ With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally.
■"Sleep breath pause syndrome analysis", the physician could print sleep asphyxia
analysis report and diagnose.
■"HRT" analysis, when the adjustable function is natural, this transitory change
will be represented by the form of HRT immediately.
■15."T Wave Alternation" analysis is a important index on judging and preventing arrhythmia.