EBM-5 Electric Medical Bed
The EBM-5 is a high-end electric medical bed used in ICUs. It has five main functions, all controlled by a motor, allowing for adjustments to the backrest, leg rest, bed height, and specialized medical tilting positions for optimal patient care and recovery.
Key Functions & Specifications
The “5 functions” typically refer to the following motorized adjustments:
Backrest Lifting: Adjustable from 0° to approximately 70°–80°.
Knee/Leg Rest: Adjustable from 0° to approximately 30°–45°.
Height Adjustment: The entire bed can be raised or lowered (typically between 490mm and 790mm) to assist with patient transfers and caregiver ergonomics.
Trendelenburg Position: Tilts the bed so the feet are higher than the head (approx. 12°–15°).
Reverse Trendelenburg: Tilts the bed so the head is higher than the feet (approx. 12°–24°).
Related products
AEONMED VG70 ICU VENTILATOR
Biphasic Defibrillator STAT-X Visor HealthCare U.K
Compression Therapy Venaflow 600 – Visor Healthcare U.K
Technical Specifications:
-
- Pressure Range: 0 mmHg to 280 mmHg.
- Screen Size: 4.3" Color touch TFT Screen
- Therapy Modes: Above 20 Therapy Modes , 8 Customizable
- Simultaneously : Simultaneously Compression of both Legs
- Maximum Pressure: 160 mmHg to 280 mmHg.
- Ultimate System Limit: ≤ 300 mmHg (with comprehensive over-pressure safety protection).
- Pressure Settings Accuracy: Adjustment steps of 5 mmHg with a strict tolerance error of ±5 mmHg.
- Therapy Timer: 0 min to 60 min (Timing error bounds: ±2% or ±1 min).
- Inflation Rate Control: 1 to 6 fully adjustable speed levels.
- System Leaks Tolerance: Maximum gas path air leakage rate ≤ 2 mmHg per second.
- Venous Filling Target: 20 seconds to 70 seconds cycle capability (Error: ≤ ±1s).
- Pressure Holding Interval: 1 second to 3 seconds hold duration (Error: ≤ ±0.5s).
- Aeration & Release Cycles: Aeration duration ≤ 25s; standard release timing ≤ 15s.
- Manual Pressure Relief Emergency: Drops down to 15 mmHg in ≤ 10 seconds.
- Power Parameters: Universal 100–240V AC input, operating at 50/60Hz ±1Hz frequency.
- Battery Architecture: Built-in 2200mAh rechargeable Lithium-ion battery pack.
- IPCT: Intermittent Pneumatic Compression Therapy
- DVT : Deep Vein Thrombosis Device
Hill-Rom VersaCare Hospital Patient Bed
Infusion Pump IP-01
- 3 inch color touch screen for easy operation and clear vision
- Compact and lightweight design for easy carrying and mounting
- User friendly interface with audible and visual alarm system
- Built-in lithium battery, around 3 to 5 hours working time after fully charged
- Multiple infusion modes to satisfy different infusion requirements
- Advanced pressure detection technology
- Infusion modes ml/h(default): Flow rate & volume mode, Flow rate & time mode, Flow rate mode d/min: Drip& volume mode, Drip& time mode, Drip mode
- Flow rate range1-1500ml/h 0.1-100ml/h, increment 0.1ml/h 101-1500mlml/h, increment 1ml/h
Patient warming System Astramed – AMPW20
UniFusion VP50 Infusion Pump
Vein Finder VX500 – MDX USA
- Light Source: Near Infrared (NIR)
- Wave Length: 850nm
- Projector Resolution: 854 × 480 pixels
- Resolution Speed: 60 frames per second
- Resolution Deviation: ≤ 0.10mm
- Maximum Detection Depth: ≤ 8mm
- Best Projection Distance: 200 ± 20mm
- Minimum Identified Vessel Diameter: ≥ 0.4mm
- Main Unit Power Consumption: 50VA
- Power Adapter Input: 100~240V AC, 50/60HZ
- Power Adapter Output: 12V DC, 2.5A
- Internal Battery: 7.2V 2200mAh Lithium-ion battery.
- Battery Working Time: ≥ 2.5 hours continuous use.
- Sleeping Function: Automatic power-saving sleep state after 30 minutes of inactivity.

Reviews
There are no reviews yet.